Part Number Hot Search : 
18000 FDD5N50F DG413 REF02HJ8 LA7161BV 28120 5253B C162244
Product Description
Full Text Search
 

To Download LDP200-120 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  ldp 200 - 120 is the first user programmable unit on the market that can supply any voltage between 24 and 120 vdc, offering unmatched flexibility for many applications. its compact size, high efficiency, excellent reliability together with easy installation makes it i deal for various industrial applications. ldp200 - 120 is class i isolation device suitable for selv and pelv circuitry and is designed to be mount ed on din rail and installed inside a protective enclosure. ? high efficiency and compact size ? active pfc ? digital control ? wide input voltage range 170 C 550 v ac ? wide output voltage range 24 C 120 v dc , user settable ? user settable current limitation threshold ? remote on/off or other remote control functions ? modbus over rs - 485 interface ? multiple protections ? 2 user programmable voltage steps with settable duration ? can be used as battery charger (lead acid, nickel, lithium) ? can be used for led lighting ? parallelable for power or redundancy (with external oring module) ? up to 50c operating temperature with no derating ? industrial control ? communication ? instrumentation equipment ? renewable energy systems
2 ldp200 - 120 tech.support@psbel.com ldp200 - 120 2 5 0 - 5 00 v ac / 250 C 725 vdc 24 - 120 v dc 4 a max * * 4.0 a @ 24 vdc, 3 a @ 48 vdc, or vout x iout = 200 w max. for vout > 48 vdc technical parameters are typical, measured in laboratory environment at 25c and 400 v ac / 50 hz, at nominal values, after minimum 5 minutes of operation. input ac voltage range s ingle or two p hases operating 200 - 500 vac 170 - 5 50 vac input dc voltage range 250 C 725 vdc input frequency 47 - 63 hz input ac current v in = 200 vac v in = 500 vac 1.4 a 0.5 a input dc current vin = 25 0 vdc v in = 725 vdc 1 a 0.4 a inrush peak current 50 a standby p ower < 4 w power factor correction active > 0.9 touch (leakage) c urrent 0.4 ma internal protection f use none, external fuse must be provided recommended external protection it is strongly recommended to provide external surge arresters (spd) according to local regulations. mcb 10 a , c curve output power 200 w rated voltage 1 v resolution programmable 24 C 120 vdc continuous current or v out x iout = max. 200 w for v out > 48 v 4.0 a @ 24 vdc / 3.0 a @ 48 vdc, overload limit vout dependant 4.4 a to 1.9 a short circuit peak current vout dependant 4.9 a to 2.2 a load regulation 1% ripple & noise 1 2 00 mvpp hold up time 25 ms battery charger function c.c. / c.v. (setup via front panel or powermaster application) battery chemistries protections overload and short circuit protection thermal protection input undervoltage lockout (uvlo) input overvoltage protection (vdr) status signals 7 segment, 3 digits display 3 programming keys enable - isolated remote on/off input, active for 5 C 30 vdc dc ok - dry contact (no, 24 vdc / 1a) modbus over rs - 485 interface, to be used with powermaster or other applications
ldp200 - 12 0 3 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2016 bel power solutions & protection bcd.00 873 _a b parallel c onnection possible for power and redundancy (with external oring m odule) efficiency vout dependant > 82% to > 90% dissipated power < 21 w 1 ripple and noise are measured with 20 mhz bandwidth, probe terminated with a 0.1 f mkp parallel capacitor. operating temperature overtemperature protection start - up type tested: - 40oc 2 - 40 to + 7 0c storage temperature - 40 to + 8 0c temperature derating 3 over 60 vdc: under 60 vdc : - 1.5 w/c over 50c - 3.0 w/c over 50c humidity non - condensing 5 C 95% rh life time expectancy a t 25c ambient full load 71686 h (8.1 years) overvoltage category pollution degree ii i (en50178) 2 ( iec60664 - 1 ) isolation voltage input to output input to ground output to ground 4.2 kvdc 2.2 kvdc 0.75 kvdc safety standards & approvals ul508 (reference) en60950 (reference) en50178 (reference) emc standards immunity: en61000 - 4 - 2 en61000 - 4 - 3 en61000 - 4 - 4 en61000 - 4 - 5 en61000 - 4 - 11 level 3 level 3 level 3 level 4 level 2 emission: en55011 (cispr11) en55022 (cispr22) en61000 - 3 - 2 class a class a class a protection degree en60529 ip20 vibration sinusoidal iec 60068 - 2 - 6 5 - 17.8 hz: 1.6mm; 17.8 - 500 hz: 2 g 2 hours / axis (x,y,z) shock iec 60068 - 2 - 27 30 g 6 ms, 20 g 11ms; 3 bu mps / direction, 18 bumps total 2 possible at no minal voltage with load derating . 3 see figure 1. weight 0.75 k g dimensions (w x h x d) 80 x 120 x 10 2 mm mounting rail iec 60715/h15/th35 - 7.5( - 15) in/out connection t erminals screw type pluggable (24 - 12 awg) 2.5 mm2 auxiliary connection terminals fast pluggable type (20 awg) up to 0. 5 mm2 communication interface connector rs - 485 through rj45 female case material aluminum notes : power rating, losses, efficiency, ripple, thermal behaviour and start - up may change outside of the nominal rated input range. contact factory for details.
4 ldp200 - 120 tech.support@psbel.com figure 1. d er ating curves figure 2 . mechanical dr awing
ldp200 - 12 0 5 asia - pacific +86 755 298 85888 europe, middle east +353 61 225 977 north america +1 408 785 5200 ? 2016 bel power solutions & protection bcd.00 873 _a b input connection o utput connection signaling single phase: l1 = line n = neutral = earth ground + = positive dc - = negative dc dc ok: dry contact 24 vdc / 1a + = n o - = com two phase: l1 = phase 1 l2 = phase 2 = e arth ground rs - 485 pin4 = tx/rx d1 pin 5 = tx /rx d0 pin 8 = gnd dc: l1 = + positive dc l2 = - negative dc = e arth ground enable: (5 C 30 vdc) + = positive dc - = negative dc 1 ac input 2 enable input 3 dc ok dry contact 4 dc output (load) 5 set button menu 6 up button menu 7 down button menu 8 display 9 rs - 485 comm. port nuclear and medical applications - products are not designed or intended for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems. technical revisions - the appeara nce of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. specifications are subject to change without notice.


▲Up To Search▲   

 